實(shi)驗室凍(dong)幹機(ji)是實驗室真(zhen)空(kong)冷凍(dong)幹燥的壹種(zhong)裝(zhuang)置,主要(yao)用於(yu)實驗研(yan)發(fa)真(zhen)空(kong)冷凍(dong)幹燥物(wu)料用途。
根據用途實驗室凍(dong)幹機(ji)有普通型凍(dong)幹機(ji)、壓蓋(gai)型凍(dong)幹機(ji)、多歧管(guan)凍(dong)幹機(ji)等用於(yu)做(zuo)不同實驗物(wu)料。同時(shi)需要研(yan)發(fa)凍(dong)幹工(gong)藝時(shi)需要確(que)定(ding)物(wu)料的共晶(jing)點和共熔(rong)點(dian),可以選(xuan)配共晶(jing)點測(ce)試儀。在實(shi)驗科(ke)研人(ren)員(yuan)選(xuan)擇凍(dong)幹機(ji)時(shi),需要確(que)定(ding)實(shi)驗要(yao)求(qiu),如果單純(chun)是做(zuo)凍(dong)幹實(shi)驗,普通鐘(zhong)罩式凍(dong)幹機(ji)就(jiu)可以。大(da)部(bu)分實(shi)驗需(xu)要確定(ding)凍(dong)幹的效率(lv)為(wei)後(hou)期(qi)轉化(hua)生(sheng)產使(shi)用,所以凍(dong)幹工(gong)藝在凍(dong)幹生(sheng)產是及其(qi)重(zhong)要。根(gen)據藥(yao)品凍(dong)幹、食(shi)品凍(dong)幹、工(gong)業(ye)品凍(dong)幹等類別(bie)要求(qiu)不壹樣(yang),選(xuan)擇凍(dong)幹機(ji)設(she)備(bei)功能和精密(mi)度(du)會有不同。
實驗室凍(dong)幹機(ji)根據(ju)發(fa)展(zhan)分(fen)為(wei)鐘(zhong)罩式凍(dong)幹機(ji)、小(xiao)型(xing)原(yuan)位凍(dong)幹機(ji),中式凍(dong)幹機(ji)等,其(qi)中鐘(zhong)罩式凍(dong)幹機(ji)FD系列(lie)分(fen)為(wei):普通型、壓蓋(gai)型、多歧管(guan)型(xing)和多歧管(guan)壓(ya)蓋型(xing)。原(yuan)位預凍(dong)凍(dong)幹機(ji)是在鐘(zhong)罩式凍(dong)幹機(ji)基礎(chu)上升級(ji)的冷凍(dong)幹燥機,具有原(yuan)位預凍(dong)、工藝設(she)定(ding)和修(xiu)改(gai)、數(shu)據記(ji)錄和存(cun)儲(chu)、凍(dong)幹曲(qu)線等功能,是實驗凍(dong)幹工(gong)藝研發(fa)的凍(dong)幹機(ji)。通常(chang)實(shi)驗室凍(dong)幹物(wu)料量(liang)比(bi)較少,所以實驗室凍(dong)幹機(ji)設(she)計都(dou)按(an)小(xiao)型(xing)設(she)計和生產(chan),根據(ju)實(shi)驗物(wu)料量(liang)的要求(qiu),在增(zeng)加處理(li)量(liang)時(shi)小(xiao)型(xing)實(shi)驗室凍(dong)幹機(ji)滿足不了要(yao)求(qiu),中式凍(dong)幹機(ji)可以處理(li)2KG以上的原(yuan)料量(liang),同樣中式凍(dong)幹機(ji)具有PLC電控(kong)系(xi)統,壹(yi)鍵啟動(dong),全(quan)自(zi)動運(yun)行的智能凍(dong)幹機(ji)。
下面(mian)我(wo)們來看看實(shi)驗室凍(dong)幹機(ji)的使(shi)用註意事項:
1、實(shi)驗室凍(dong)幹機(ji)必(bi)須(xu)使(shi)用獨(du)立(li)電(dian)源(yuan)插座有良(liang)好接(jie)地。
2、實(shi)驗室凍(dong)幹機(ji)須(xu)在環(huan)境(jing)溫度(du)在5-30℃下(xia)工作(zuo),這(zhe)樣有利於(yu)延長壓縮機(ji)壽(shou)命,壓機(ji)長(chang)期(qi)在30℃以上會造(zao)成(cheng)壓(ya)縮機(ji)損(sun)壞。
3、制冷(leng)系統二(er)次(ci)啟動(dong),須(xu)在3分(fen)鐘(zhong)之後(hou),這(zhe)樣有利於(yu)壓機(ji)壽(shou)命
4、如果托盤及(ji)外(wai)掛凍(dong)幹瓶(ping)同時(shi)使(shi)用,先放(fang)托盤物(wu)料,待(dai)半(ban)小(xiao)時(shi)後(hou)制冷溫度(du)為(wei)-50℃或(huo)-80℃、壓(ya)力(li)為(wei)30mTorr時(shi)再外掛凍(dong)幹瓶(ping),以免使(shi)掛瓶物(wu)料融化(hua)
5、物(wu)料必(bi)須(xu)凍(dong)實,預凍(dong)溫度(du)在-30℃以下,凍(dong)幹樣(yang)品非(fei)水(shui)溶(rong)解(jie)物(wu)(如有機溶(rong)解(jie)物(wu)、或(huo)者(zhe)為(wei)80%以上高濃度(du)的糖(tang)類等不易結(jie)凍(dong)的樣品,須(xu)在-80℃以下的預凍(dong)室內預凍(dong),預凍(dong)時(shi)間不小(xiao)於(yu)24小(xiao)時(shi),在48小(xiao)時(shi)以上。
6、有機玻(bo)璃(li)凍(dong)幹倉(cang)取(qu)下時(shi),必(bi)須(xu)輕放(fang)在橡(xiang)膠等柔軟(ruan)物(wu)體(ti)上,以免有機玻(bo)璃(li)受(shou)損(sun)而漏(lou)真(zhen)空(kong)
7、所放(fang)物(wu)料的多少(shao)與(yu)環境(jing)溫度(du)的高低有關,冷(leng)阱(jing)溫度(du)在-55℃至(zhi)-40℃或(huo)-85℃至(zhi)-80℃及(ji)真(zhen)空(kong)度(du)在5-100mTorr均(jun)為(wei)正(zheng)常(chang)。
8、 空(kong)氣(qi)回填(tian)時(shi),請(qing)將通(tong)入真(zhen)空(kong)回填(tian)氣(qi)體壓(ya)力調至0.5Kg以下。
9、 實驗室凍(dong)幹機(ji)距墻面(mian)距離(li)≥30cm。
10、禁(jin)止將其(qi)他散(san)熱(re)設(she)備(bei)放(fang)在實(shi)驗室凍(dong)幹機(ji)附(fu)近,造(zao)成(cheng)制(zhi)冷(leng)系(xi)統無(wu)法(fa)散(san)熱(re),致(zhi)使(shi)儀器不能工(gong)作(zuo)及(ji)壓縮機(ji)損(sun)壞。
11、設(she)備(bei)放(fang)置平穩後(hou),將腳輪固(gu)定(ding)器(qi)按(an)下(xia)。
12、操(cao)作(zuo)前觀察(cha)真(zhen)空(kong)泵油位及(ji)油質(zhi)。
13、抽真(zhen)*將排水管(guan)堵(du)上,適配器(qi)系(xi)統全(quan)部(bu)關(guan)閉,否則會(hui)造(zao)成(cheng)真(zhen)空(kong)泵損(sun)壞。
14、壓縮機(ji)及(ji)冷(leng)凝器翅片定(ding)期(qi)除塵。